Canadian Exclusive Dealer

 

Home              Products and Solutions               Login            Links             Quotations            Contact Us

SolarBeeŽ

 

   Fresh Water  

  

   Potable Water  

  

   Wastewater

  

   Industrial Applications

  

   Specifications

 

Case Studies/

   Testimonials

  

   News Articles

  

   Videos  

  

   Photos

 

Case Studies and Testimonials

Case Study for Customer Location WY52:

Reservoir or Lake Use:
Municipal wastewater treatment system for 1200 residents. Most critical discharge permit limits are: 4.1 mg/L ammonia-N, summer, 10.1 mg/L ammonia-N winter, 30 mg/L BOD, 50 mg/L total suspended solids (TSS).

System Overview and Reservoir:
Flow rate through system is 0.12 MGD, with 100% of the flow to Pond 1, then to Pond 2, then Pond 3. System has controlled periodic discharge. Total system detention time is 29 days. Pond 1: 0.5 acres, 8 ft deep, 0.8M gallons, loading is 480 lbs of BOD/acre/day, has installed 30 hp of grid aeration, was operating it 24 hours per day. Pond 2: 0.5 acres, 8 ft deep, 0.8M gallons, has installed 15 hp of grid aeration, was operating it 24 hours per day. Pond 3: 1.1 acres, 8 ft deep, 2.0M gallons, has no grid aeration.

Reported Problem Before Installation:
High ammonia, some odors, high BOD and TSS, energy costs.

Installation:
Date: December 2000, installed one (1) unit equal to SB2500 with 24-hour electrical kit into Pond 2 and a similar unit into Pond 3. March 2002, installed one (1) unit equal to SB2500 with 24-hour electrical kit into Pond 1. December 2002, units in all three ponds were upgraded to SB10000s. September 2003, the SB10000s were replaced with the new SB10000-DM (duel mix) units.

Results:
The first units installed in Pond 2 and 3 totally eliminated aerator run time in Pond 2, and reduced odors. The pH remained around 8.0 and ammonia concentrations still stayed high at 12.2 mg/L (annual average). After the 3rd machine was added to Pond 1 in March 2002, it brought up the next 8 months average pH to 8.36, and the average ammonia down to 9.83 mg/L for a 20% reduction. Electricity costs dropped from $14K to $4K (i.e., $10,000 savings) as the aerator in Pond 1 was reduced to 8-10 hours per day. This aerator was turning on several times per day instead of being off all day, which reduced the effectiveness in raising the pH. After the duel mix units were installed in September 2003 and aeration timing corrected, great improvements were made in reaching effluent discharge limits and the SolarBees have met performance expectations since.


Back to Case Studies Index

 

 

 